How Much Do Compressed Air Leaks Cost?
Ekran detektora LD 510 wskazujący miejsce nieszczelności oraz poziom sygnału 51,1 dB i stratę powietrza 1,8 l/min.

How to Calculate Losses and Prioritise Repairs

The production shift has ended, but the compressed air system remains pressurised. A leaking pipe connection can therefore continue consuming air even when the machine is not completing a single cycle. Assessing the cost of that loss requires more than knowing that “something is hissing”.

The key factors are the leakage flow rate, the number of hours the system remains pressurised, the energy consumption of the compressor installation and the electricity price. Below, we explain how to combine these inputs, create a leak register and select repairs that make both technical and economic sense.

How can you estimate the cost?

Energy cost attributable to a leak = annual volume of air lost × specific energy consumption × electricity price. Calculate the volume from the leakage flow rate and the hours during which the leak occurs. The result represents the energy cost allocated to the air loss. Actual savings after repair also depend on how the compressors respond to the reduced air demand.

Osoba ze słuchawkami kieruje detektor ultradźwiękowy na instalację rurową

Why do leaks still cost money after production has stopped?

Production hours versus hours under pressure

Switching off a machine does not necessarily isolate its compressed air supply. If the leaking section remains pressurised, air continues to escape. The compressor installation must replace these losses for as long as it maintains the supply to that part of the network.

For this reason, use the time during which the leak occurs at the assumed pressure, rather than automatically using production hours. A workstation operating for 4,000 hours per year may remain connected to a pressurised supply for considerably longer. Conversely, a section isolated after each shift should not be assigned the full annual operating hours of the compressor installation. Where pressure varies, divide the calculation into periods with different operating conditions.

Where do leaks most commonly occur?

Inspect threaded connections, quick-release couplings, machine hoses and tubing, valves and fittings, compressed air preparation equipment, and condensate drains. Distinguish a fault from intentional venting required for equipment operation. Not every discharge of air is a leak, although intentional air consumption may also offer opportunities for optimisation.

When assessing the entire network, refer to our guide to pneumatic system design and maintenance .

What data should you collect before calculating leakage costs?

A reliable calculation starts with consistent units and clearly stated assumptions. A reading of “60 l/min” is incomplete unless the reference conditions for the air volume are known.

Flow rate, pressure and reference conditions

The volumetric flow rate of the same air stream changes with pressure and temperature. The flow rate inside a pressurised pipe is therefore not the same as the flow rate converted to reference conditions. The symbol Nm³ requires the adopted normal conditions to be specified. FAD, or free air delivery, expresses compressor delivery referred to specified inlet conditions; it is not automatically equivalent to a flow expressed in normal cubic metres.

Check the measurement basis in the instrument documentation and settings. Specific energy consumption must refer to the same reference volume. We discuss the properties of the working medium in more detail in our article on compressed air and air treatment .

Input data: what to collect and what to check
Parameter Where to obtain it What to check
Leakage flow rate, l/min or m³/h Measurement or documented estimate Reference conditions, method and measurement uncertainty
Pressure at the leak location Measurement taken during the survey bar(g) denotes gauge pressure relative to atmospheric pressure; bar(a) denotes absolute pressure
Hours under pressure, h/year Pressurisation schedule for the surveyed area Include nights, weekends and isolation periods
Specific energy consumption, kWh/m³ Consistent energy and air-volume data Use the same system boundary, measurement period and volume reference conditions
Electricity price, PLN/kWh Agreed rate based on electricity billing data Separate consumption-dependent charges from fixed charges

Pressurisation hours, energy consumption and electricity price

Specific energy consumption should ideally be determined under representative operating conditions for the compressor installation. If you use catalogue data, record the conditions for which the value is specified. Motor nameplate power is not a substitute for measuring actual energy consumption.

Establish whether the amounts include or exclude VAT. When calculating savings, do not assume that fixed charges will automatically disappear after repairs. The model below covers energy costs only; it does not represent the full cost of compressed air, including depreciation and servicing.

How do you measure leakage, and what does hissing alone tell you?

Ultrasonic detection of individual leaks

An ultrasonic leak detector helps locate the source of a leak. Instruments such as the LD 500/510 also provide functions for estimating leakage flow and documenting leak locations. However, locating a leak and quantifying it are different tasks. The result depends on the correct method, instrument settings and survey conditions. [1]

How audible a leak is depends partly on the surroundings and the geometry of the location. Do not convert perceived loudness into litres or monetary losses by ear. Record the identifier, location, method, pressure and result in the register. A photograph helps the repair team find the same point.

Detektor ultradźwiękowy CS Instruments LD 510 ze słuchawkami

The pressure-decay method for an isolated section

Total leakage can be assessed from the pressure drop in a known volume. The section under test must be isolated from the air supply and intentional air consumption. Its actual volume must be known, and temperature effects must be considered. Temperature changes can alter pressure even when no air is lost.

The result represents average leakage over the tested pressure range. It does not automatically give the flow rate of every individual leak at nominal pressure. For a preliminary assessment, use the pressure-decay leakage calculator . Interpret the result in the context of the test conditions.

Estimating leakage from orifice diameter requires assumptions

Cost tables for 1, 2 or 3 mm openings can illustrate the scale of losses, but they are not a universal price list. The result depends on pressure, orifice geometry and the parameters adopted in the model. Base repair decisions on data applicable to the actual installation.

How do you convert leakage from l/min into PLN per year?

Enter four quantities: flow rate qref in reference litres per minute, time h in hours per year, specific energy consumption eref in kWh/m³ref, and electricity price ce in PLN/kWh. The subscript “ref” indicates that flow and volume use the same defined reference conditions.

Step 1: calculate the annual volume of air lost

Vref = qref × 60 / 1000 × h

Multiplying by 60 converts the per-minute rate to an hourly rate, while dividing by 1,000 converts litres into cubic metres. The result is expressed in m³ref/year. If the flow rate or operating schedule changes, calculate each period separately and add the volumes.

Step 2: calculate the attributable energy and cost

Eattr = Vref × eref

Cattr = Eattr × ce

The first result is the energy attributable to the leak in kWh/year; the second is its cost in PLN/year. This is an accounting model. It does not, by itself, confirm that energy consumption will decrease by exactly that amount after repair.

Example: a 60 l/min leak over 8,000 pressurised hours

  1. Hourly flow: 3.6 m³ref/h
    60 × 60 / 1000
  2. Annual volume: 28,800 m³ref
    3.6 × 8000
  3. Attributable energy: 3,168 kWh/year
    28,800 × 0.11
  4. Attributable cost: PLN 2,851.20/year
    3,168 × 0.90

At 4,000 pressurised hours, with all other assumptions unchanged, the result is PLN 1,425.60 per year. This is why the pressurisation schedule matters just as much as the leakage flow rate.

We do not multiply the result by 7 bar again: the flow rate has already been referred to specified conditions. If the data are expressed as volume at operating conditions, they must first be converted using absolute temperatures and absolute pressures.

A five-leak register: from measurements to an action list

A separate entry for each leak links diagnosis, cost assessment and repair verification. This turns a general observation that “the system is leaking” into actionable information.

Technical data and estimated annual cost

How much does leakage cost?

Illustrative compressed air losses and their attributable energy cost.

Total illustrative annual cost, excluding VAT
8,256.60 PLN/year
83,400 m³ref of air · 9,174 kWh of energy per year

On smaller screens, scroll the table horizontally to view all columns.

Table 1. Illustrative air losses and attributable energy costs
ID and location Flow rate lref/min Time h/year Volume m³ref/year Energy kWh/year Cost excluding VAT PLN/year
W01
Assembly workstation quick-release coupling
25 6,000 9,000 990 891.00
W02
Pipe connection on a continuously pressurised line
60 8,000 28,800 3,168 2,851.20
W03
Valve assembly on a section requiring a shutdown
120 4,000 28,800 3,168 2,851.20
W04
Leaking condensate drain in a continuously pressurised area
15 8,000 7,200 792 712.80
W05
Connection at a less frequently pressurised workstation
80 2,000 9,600 1,056 950.40
Total — — 83,400 9,174 8,256.60

Annual energy cost by leak location

Cost excluding VAT in PLN/year · scale starts at zero

Illustrative annual energy costs attributable to leakage, excluding VAT. Table 1 provides the complete data and units.

Repair plan and priorities

Illustrative repair costs, payback periods and implementation requirements for the identified leaks.

On smaller screens, scroll the table horizontally to view all columns.

Table 2. Illustrative repair decisions
ID Repair cost excluding VAT Payback* months Criticality and access Priority Status in the scenario
W01 PLN 180 2.42 months Low; easy access P1 To be scheduled
W02 PLN 400 1.68 months Medium; brief isolation of the area required P1 To be scheduled
W03 PLN 1,200 5.05 months The process is highly dependent on this section;
a shutdown is required
P2 Agree a shutdown window
W04 PLN 250 4.21 months Medium; check condensate drainage functionality P1 Technical assessment
W05 PLN 900 11.36 months Low; restricted access P3 Combine with scheduled maintenance
Total PLN 2,930 Illustrative repair cost excluding VAT and the shared audit cost

*Payback assumes complete elimination of the leak and a linear reduction in energy consumption. It is not guaranteed. Illustrative repair costs include the incremental costs associated with each point and, for W03, the arrangements for the agreed shutdown. They exclude the shared audit cost.

Which leaks should you repair first, and how do you calculate payback?

Start with safety and process criticality

The largest leak should not automatically be the first repair. Assess hazards and process impact first. A damaged hose or malfunctioning valve assembly may require action regardless of the financial calculation. Repairs must be carried out after safely isolating and depressurising the relevant part of the system in accordance with site procedures.

No P0 priority has been assigned in this example. P0 denotes a hazard requiring action under the applicable safety procedures. A payback table cannot replace that assessment.

Then consider savings, cost and repair feasibility

P1 covers prompt actions with a favourable benefit-to-cost ratio or actions important to equipment operation. P2 denotes work requiring preparation and an agreed shutdown. P3 allows a repair to be combined with scheduled maintenance if the equipment condition does not require earlier intervention. Final priorities are approved by the maintenance team.

Include parts, labour, access, testing and the additional cost of any required downtime in the repair cost. Account for shared audit or mobilisation costs once at programme level, or allocate them explicitly. For recurring leaks, also check pneumatic fitting selection , installation quality and mechanical loading on the hose or tubing.

Simple payback versus actual financial benefit

Payback period [months] = repair cost / annual net savings × 12

The illustrative repair cost for W02 is PLN 400. If annual savings reach PLN 2,851.20, the payback period will be approximately 1.68 months. If the achieved energy savings are half that amount, payback increases to 3.37 months. These are two scenarios, not a forecast of typical repair effectiveness.

The denominator should contain the expected savings after allowing for the response of the compressor installation and any additional operating costs. If net savings are zero or negative, there is no positive simple payback period. Do not call this indicator ROI: return on investment compares net benefits with the investment over a defined time horizon.

How can you verify that repairs have actually reduced costs?

Recheck the same leak location

Return to the tagged location after the repair. Repeat the test using comparable pressure, methods and settings. Record the date and result. The absence of audible hissing is not sufficient to claim zero leakage; the result must also be interpreted in relation to the capabilities and uncertainty of the measurement method.

Compare flow and energy under similar load conditions

Eliminating a leak confirms that the repair at that point has been effective. Confirming a lower electricity bill requires a separate assessment of the compressor installation. Compare representative periods before and after the work, allowing for production output, operating schedules, pressure and other system changes. Lower kWh consumption during a week with lower production is not, by itself, evidence that the repair programme has delivered savings.

Monitor energy consumption, delivered air volume and compressor operating modes together. Keep the measurement boundary consistent: do not compare motor-only consumption before the repair with the consumption of the entire compressor installation afterwards.

Compressor controls and follow-up leak inspections

After leakage has been reduced, a compressor may spend longer running unloaded instead of switching off. Consequently, energy savings may be lower than a simple calculation based on air volume and average specific energy consumption suggests. Reassessing compressor controls after repairs is therefore worthwhile; this approach is also recommended in DOE/ENERGY STAR guidance. [2] Any changes must account for the requirements of the air-consuming equipment. Further context is provided in our guide to compressor selection and operating conditions .

Keep the register as a working document. Update it after modifications, hose and pipework changes, and subsequent inspections. Set inspection intervals according to area criticality, fault history and operating conditions.

CPP PREMA compressed air leak audit

When should you consider an audit?

Consider an audit when there are numerous leak locations, parts of the installation are difficult to access, losses recur, or there is insufficient data to justify a repair budget. A structured report turns measurements into an action list for the maintenance team.

What does the audit include?

A CPP PREMA compressed air leak audit includes:

  • Locating individual leaks.
  • Photographic documentation.
  • Calculating losses using agreed assumptions.
  • Assigning repair priorities.

Separately agreed scope:
Any repairs and energy measurements of the compressor installation. These are not automatically included in leak detection alone.

What should you prepare for the initial discussion?

  • The system boundaries and areas supplied with compressed air.
  • Operating pressure.
  • Pressurisation hours and operating schedules.
  • Information on access to measurement locations.
  • Contact details for the people responsible for maintenance and the compressor installation.

Missing some parameters?
Identify the gaps rather than replacing them with arbitrary values.

Frequently asked questions about compressed air leakage costs

Can a small leak generate significant costs?

Yes, particularly if it persists for many hours or if there are numerous similar leaks. In the model used in this article, 15 lref/min over 8,000 hours results in an annual energy cost of PLN 712.80. This amount applies only to the stated assumptions.

Can losses be calculated without measuring flow?

They can be estimated, for example using pressure decay in a known volume or an orifice model. The limitations of the method must be understood and the assumptions recorded. A preliminary estimate should not be presented as an exact measurement of an individual leak.

Does a louder leak always mean a greater loss?

No. Audibility is affected by geometry, distance and ambient noise. Repair priorities should be based on technical and quantitative assessment, rather than solely on which leak is easiest to hear.

Does the system lose air after the shift ends?

Yes, if the leaking section remains pressurised. If it is isolated and depressurised, its annual leakage duration will differ from the operating hours of the compressor installation. The calculation must reflect the actual schedule for that area.

Does repairing leaks reduce electricity consumption proportionally?

Not always. Reducing air demand changes compressor loading, but the outcome depends on compressor controls and the operating profile. Confirming savings requires a comparison of energy consumption under comparable production conditions.

How do you verify that a repair has been effective?

Retest the same point, record the conditions and result, and update the register. Separately assess the effect of the repair programme on system flow and energy consumption. A “repaired” status does not replace post-repair verification.

How often should the system be checked for leaks?

The schedule depends on system criticality, fault history, vibration, pipework changes and operating conditions. Coordinate leak checks with maintenance and modification work. There is no single inspection interval suitable for every facility.

What information should be prepared before an audit?

Prepare the system scope, pressure, pressurisation schedule, electricity cost or agreed assumptions, access information, and contact details for the maintenance and compressor installation teams. A list of recurring leak locations is also useful.

Sources and assumptions

All amounts in the example are illustrative and exclude VAT. The tables do not document completed audits or guaranteed savings. The source materials were checked on 12 October 2026.